We specialize in Purified water storage and distribution systems . Proper storage and controlled distribution are crucial for maintaining the integrity and quality of these pharmaceutical waters. Our advanced systems meet the specific requirements, ensuring purity and sterility. We use compliant stainless-steel tanks and containers, providing a secure environment. Monitoring capabilities maintain optimal conditions. Our precise distribution systems deliver PW and WFI to various points within pharmaceutical facilities. They comply with regulations and prevent contamination or degradation during transportation. We prioritize safety, purity, and reliability, offering customized solutions for small-scale to large facilities. With our cutting-edge systems, your PW and WFI will meet the highest quality standards, ensuring the integrity and safety of your pharmaceutical products. Pharmaceutical facilities can maintain the purity, sterility, and compliance of PW and WFI by utilizing specialized stainless-steel tanks and implementing a controlled distribution process. These tanks are designed to meet strict industry standards and are equipped with features that safeguard the quality of the stored water. With our advanced purified water storage and distribution systems, you can trust in the integrity and safety of your PW and WFI, ensuring the quality and efficacy of your pharmaceutical products.

1

Storage Process

 

After purification, the PW and WFI are stored in specialized tanks specifically designed for pharmaceutical applications. These tanks are typically made of high-grade stainless steel, which offers excellent corrosion resistance, durability, and ease of cleaning. The tanks are engineered to maintain the purity and sterility of the stored water, with features such as smooth internal surfaces, sanitary fittings, and hermetically sealed closures. Temperature and humidity control systems are implemented to maintain optimal storage conditions, minimizing the risk of microbial growth or degradation.

_
2

Distribution Process

 

When it comes to distribution, the stored PW and WFI are carefully transported to various points of use within the pharmaceutical facility. Distribution systems consist of a network of pipes, valves, and fittings that ensure the controlled flow of water. These systems are designed to prevent backflow, minimize dead legs, and eliminate the potential for contamination during transportation. Flow meters, pressure sensors, and monitoring devices are incorporated to maintain the required flow rate and pressure throughout the distribution network

_
3

Monitoring and Validation

 

Storage and distribution processes require rigorous monitoring to comply with regulations. Temperature, pressure, conductivity, and microbial levels are continuously tracked to ensure PW and WFI quality. Advanced control systems provide real-time data for immediate deviation detection and correction. Regular validation, including microbial and integrity testing, ensures system effectiveness.

_